4WRTE Series High‑Response Proportional Directional Valve
Product Overview
4WRTE series are two‑stage pilot‑operated high‑response proportional directional valves with
dual closed‑loop position feedback for both pilot spool and main spool, equipped with onboard integrated OBE digital amplifier. Common pain‑points for high‑end hydraulic equipment: poor dynamic response, position drift caused by flow force, temperature drift, complicated external wiring. This valve solves these issues. It compares command signal with real‑time position feedback signals of pilot and main spool simultaneously, compensates flow‑force and temperature‑induced deviation, realizes high‑precision closed‑loop control for position, velocity and force of hydraulic actuators. Power‑off fail‑safe function: main spool returns to spring‑centered neutral position when power supply fails or cable breaks, avoiding dangerous uncontrolled movements. Available sizes NG10, NG16, NG25, NG27, NG32, ISO4401‑standard subplate mounting. Multiple pilot oil modes ET / E / T / XT. Rich spool functions E, E1, W6, W8, V, V1. Max working pressure up to 350 bar, maximum flow up to 1600 L/min. Supports ±10 V voltage or 4‑20 mA current input signal. IP65 electrical protection grade. Compatible with mineral oil and phosphate ester hydraulic fluid. ISO9001 & CE certified for heavy‑duty high‑precision industrial hydraulic systems.
Key Selling Points
- Dual closed‑loop feedback: both pilot spool and main spool with position sensor, counteracts flow‑force disturbance, suppress position drift
- Ultra‑low hysteresis<0.1 %, high sensitivity<0.05 %, low temperature drift, consistent control performance under variable working conditions
- On‑board integrated OBE digital amplifier, no external amplifier required, simplifies cabinet wiring
- Fail‑safe spring centering: power loss triggers safe return‑to‑center for machine safety
- Multiple pilot oil supply‑return combinations ET/E/T/XT, adapt various hydraulic system layouts
- Multiple spool profiles (L / P characteristic curves), supports position / speed / force closed‑loop control
- Analog input: ±10 V voltage or 4‑20 mA current signal; position feedback output available for upper‑level controller
- IP65 protection grade, suitable for harsh industrial workshop environment
- ISO4401 standard subplate mounting, interchangeable with mainstream international brands
- Compatible with mineral hydraulic oil and phosphate ester fire‑resistant fluid
- ISO9001 & CE certified
Technical Data
表格
| Item |
Specification |
| Valve Type |
Pilot‑operated high‑response proportional directional valve(Dual closed‑loop feedback) |
| Nominal Sizes |
NG10, NG16, NG25, NG27, NG32 |
| Mounting |
ISO4401 standard subplate mounting, recommended horizontal installation |
| Max Working Pressure |
P/A/B port: up to 350 bar; T port static max 10 bar; X/Y port up to 315 bar |
| Nominal Flow(@Δp=10 bar) |
25‑600 L/min;Max allowable flow up to 1600 L/min |
| Pilot Oil Modes |
ET(internal‑internal), E(internal‑external), T(external‑internal), XT(external‑external) |
| Electronics |
On‑board integrated OBE digital amplifier, dual spool position feedback |
| Control Signal |
±10 V (A1) or 4‑20 mA (F1) |
| Power Supply |
24 VDC (18‑35 VDC) |
| Protection Class |
IP65 |
| Hysteresis |
<0.1 % |
| Response Sensitivity |
<0.05 % |
| Temperature Drift |
<0.3 % /10℃ |
| Hydraulic Fluid |
Mineral hydraulic oil, phosphate ester fluid(DIN51524‑535) |
| Fluid Temperature |
‑20℃ ~ +80℃ |
| Viscosity Range |
20‑380 mm²/s (optimal:30‑45 mm²/s) |
| Required Fluid Cleanliness |
ISO4406 18/16/13 |
Typical Applications
For high‑end equipment requiring high‑dynamic closed‑loop motion control: ✅ High‑precision hydraulic test benches ✅ Metal‑forming hydraulic presses ✅ Metallurgical rolling & extrusion machinery ✅ High‑performance injection‑molding machines ✅ Synchronous multi‑axis automation production lines ✅ Material fatigue testing equipment ✅ High‑dynamic servo hydraulic systems
Important Notes
- Strictly guarantee oil cleanliness to ISO4406 18/16/13; poor oil quality will damage inner sensor and pilot stage.
- Manifold mounting‑surface requirement: flatness 0.01 mm /100 mm, surface roughness Ra0.8.
- Base plate / manifold is not included, order separately if needed.
- Tighten mounting bolts strictly follow torque value shown in dimension drawing.
- For system pressure>210 bar, external pilot oil supply(X port) is strongly recommended.
- Feedback signal cannot be used for machine safety‑related interlock functions.